Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · CFR · Title 14 — Aeronautics and Space · Part 29 — Airworthiness Standards: Transport Category Rotorcraft · § 29.1337

§ 29.1337. Powerplant instruments.

424 words·~2 min read·/us/cfr/t14/s§ 29.1337·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Instruments and instrument lines.
(1)Each powerplant and auxiliary power unit instrument line must meet the requirements of §§ 29.993 and 29.1183.
(2)Each line carrying flammable fluids under pressure must—
(i)Have restricting orifices or other safety devices at the source of pressure to prevent the escape of excessive fluid if the line fails; and
(ii)Be installed and located so that the escape of fluids would not create a hazard.
(3)Each powerplant and auxiliary power unit instrument that utilizes flammable fluids must be installed and located so that the escape of fluid would not create a hazard.
(b)Fuel quantity indicator. There must be means to indicate to the flight crew members the quantity, in gallons or equivalent units, of usable fuel in each tank during flight. In addition—
(1)Each fuel quantity indicator must be calibrated to read “zero” during level flight when the quantity of fuel remaining in the tank is equal to the unusable fuel supply determined under § 29.959;
(2)When two or more tanks are closely interconnected by a gravity feed system and vented, and when it is impossible to feed from each tank separately, at least one fuel quantity indicator must be installed;
(3)Tanks with interconnected outlets and airspaces may be treated as one tank and need not have separate indicators; and
(4)Each exposed sight gauge used as a fuel quantity indicator must be protected against damage.
(c)Fuel flowmeter system. If a fuel flowmeter system is installed, each metering component must have a means for bypassing the fuel supply if malfunction of that component severely restricts fuel flow.
(d)Oil quantity indicator. There must be a stick gauge or equivalent means to indicate the quantity of oil—
(1)In each tank; and
(2)In each transmission gearbox.
(e)Rotor drive system transmissions and gearboxes utilizing ferromagnetic materials must be equipped with chip detectors designed to indicate the presence of ferromagnetic particles resulting from damage or excessive wear within the transmission or gearbox. Each chip detector must—
(1)Be designed to provide a signal to the indicator required by § 29.1305(a)(22); and
(2)Be provided with a means to allow crewmembers to check, in flight, the function of each detector electrical circuit and signal. (Secs. 313(a), 601, and 603, 72 Stat. 759, 775, 49 U.S.C. 1354(a), 1421, and 1423; sec. 6(c), 49 U.S.C. 1655(c)) [Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 29-13, 42 FR 15047, Mar. 17, 1977; Amdt. 29-26, 53 FR 34219, Sept. 2, 1988]
Connections3 off-index
3 references not yet in our index
  • 72 Stat. 759
  • 49 USC 1354(a)
  • 49 USC 1655(c)
Citation graph
cites case law
§ 29.1337
Powerplant instruments.
Stat.72 Stat. 759
Cite49 USC 1354(a)
Cite49 USC 1655(c)
Cites 3Cited by 0 across 0 sources
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.